Set up meters
Enter up to 10 meters of the same type and size, install them in series on the test table and record each as-found reading. Then start a meter test, or run a water-use scenario through them.
1 · Meters
| # | Manufacturer | Model | Serial number | Location / account | As-found (gal) | Simulated condition |
|---|---|---|---|---|---|---|
| 1 |
|
|
|
|
|
|
Meter 1 is nearest the inlet. The meters are in series, so each one is measured against the same water.
2 · Install on the test table
3 · Test options
• Enter every serial number.
• Install the meters on the test table.
• Record every as-found register reading (0 is fine for a new meter).
Test profile
5/8" Positive displacement
AWWA C700 / M6 · default-2026.1 (verify)
| Point | Flow gpm | Volume gal | Limits |
|---|---|---|---|
| High | 15 | 10 | 98.5–101.5% |
| Intermediate | 2 | 5 | 98.5–101.5% |
| Low | 0.25 | 1 | 95.0–101.5% |
Each point runs start/stop: set the flow, stop, tare the weigh tank, read the registers, run the volume, stop, read again.